WPCP 2BTgW#|d Elite 10pt 12 pitch (D/J/M)|Lddd,#d\( @HP LaserJet Series IIHPLASEII.PRSd\( @,,,,06O2D%L Tq W#|dPrestige Elite 10pt 12 pitch (D/J/M)|Lddd,#d\( @HP LaserJet Series IIHPLASEII.PRSd\( @,,,,06O2NJN ** * * * * * * * * * REMOVE THIS OUTLINE GUIDE BEFORE PLACING THE SPECIFICATION SECTION IN THE CONTRACT )* * * * * * * * * * * 'O U T L I N E G U I D E &DIVISION 17: MISCELLANEOUSă CORROSION INVESTIGATION FOR URD CABLES SPECIFICATION NO. 17103 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * NOTICE TO DESIGNER!!! * X  * * (# X X` * 1. DO NOT USE DIVISION 1 thru 16 SPECIFICATIONS *(#` * WITH THIS SPECIFICATION. * * * * 2. Check with procurement personnel for wording * * on the following: * * * X X` * Section E Inspection *(#` * Section F Delivery * * Section G PI/COR/CO * * Section H Payments * X X` * Section J Attachments *(#` * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * USE:XContracting for an engineering investigation of corrosion on an underground high voltage distribution system of URD concentricneutral cable. Also, furnishing design documents for a corrosion protection system for this cable if needed.(# DRAWING DATA REQUIRED: Location and detail drawings as needed. The drawings show the location of anodes and anodes with test stations. REQUIRED SPEC MODIFICATIONS: -GENERAL NOTESă X` hp x (#%'X( hp x (#%'X 1.Whenever entire articles, paragraphs, or subparagraphs are not applicable, the articles, paragraphs, or subparagraphs should be deleted; when necessary, reletter or renumber articles, paragraphs, or subparagraphs.(# X 2.THIS GUIDE IS NOT INTENDED AS A SUBSTITUTE FOR READING THE ENTIRE SECTION.(#  h)Ԍ ,TECHNICAL NOTESă X 1.C.1.2: Insert BLM name of site, county, and state where work will be performed.(# X 2.C.1.3: Select or add applicable references.(# X 3.C.4.1: Insert number of copies of report required. Normally 5 copies are required. Distribution after review is normally 1 copy to the COR, 1 copy to the Contractor, 1 copy to the project file, 1 copy to the State Director (940), and 1 copy to the Service Center Director (SC673).(# X 4.E.1.0: Check with your procurement staff for proper wording.(# X 5.F.1.0: Check with your procurement staff for proper wording.(# X 6.F.2.0: Check with your procurement staff for proper wording.(# _______________________________ * * * * * * * * * * * * * * X   X$ * POINT OF CONTACT *(# DATE OF LAST REVISION: 6/2/89*0X06X6p< * Donald Mitchell (SC673)*(#p WRITTEN BY: Mitchell` !$X$h*X*0X06 * FTS 7760133 *(# REVISED BY: Porter * COMM. (303) 2360133 * APPROVED BY: )h*X*0X06 * * * * * * * * * * * * * *(# 17103 h)Ԍtx /SECTION C GEOTECHNICAL INVESTIGATIONS SPECIFICATION NO 17102 Rev. 689 t17102CX( hp x (#%'Xl( hp x (#%'xS x#  SECTION C DESCRIPTION/SPECIFICATIONS CORROSION INVESTIGATION FOR URD CABLES SPECIFICATION NO. 17103 Rev. 689 T #17103CC.1.0lGENERAL:(#l C.1.1lDescription of Work: Investigation of suspected locations of corroded neutral wires on URDtypeprimary cables. Investigation shall include field measurement to ascertain the location and extent of the corrosion, an engineering study and report to analyze and describe the findings, and a design for a cathodic protection system when one is needed.(#l C.1.2lLocation: Work under this Contract is located at the [______________] in [_________________] County, {_________________]. The work locations are shown in Section J of this contract.(#l C.1.3lReferences:(#l Xl( hp x (#%'Xl4( hp x (#%'C.1.3.14Electric Power Research Institute(#4  l4Xl4( hp x (#%'Xl4( hp x (#%'(#4  l4EPRIEL362 &An Investigation and Status Report on Concentric Neutral Corrosion of URD Extruded Cable(# C.1.3.24National Association of Corrosion Engineers(#4  l4NACE RP0174"&Corrosion Control of Electric Underground Residential Distribution Systems(# C.1.3.34Rural Electrification Administration:(#4  l4Paper  &UPR Concentric Neutral Corrosion and its Control, by Wagner, Fitzgerald, Cremers, and PCS Professional Service Group.(# C.1.4lTesting Company Qualifications: A member of NACE specializing in the field of corrosion investigation and protection. All investigation and corrosion protection design work according to NACE Standards.(#l C.2.0lCONTRACTORFURNISHED ITEMS:(#l C.2.1lCable Location: The Contractor shall have equipment available for locating underground cable. This equipment shall be used wherever the exact route of the buried cable is in doubt.(#l  !ԌC.3.0lGOVERNMENTFURNISHED PROPERTY:(#l C.3.1lSite Assistance: The Contracting Officer will provide the Contractor with a set of asbuilt construction drawings showing the location of the existing buried electrical system, trench details, jointuse trench construction and location, and other necessary information. The Contractor will be given an orientation tour of the site during which aboveground features of the system will be visited. Access will be provided to locked manholes, transformer enclosures, switch or tap enclosures after arrangement is made with the Contracting Officer.(#l C.4.0lSPECIFIC TASKS:(#l C.4.1lReport: Submit [_____] copies of an engineering report which shall include the following information: Soil Resistivity Data taken at not more than 300ft intervals along the cable route; a CabletoSoil Potential Plot with measurements taken at not more than 25ft intervals along the route; an IR Drop Diagram with readings taken at locations along the cable route where the cable neutral can be accessed; an evaluation of the effect of stray directcurrent circuits; a summary with pertinent conclusions and recommendations noted.(#l C.4.2lCathodic Protection System Design: When shown necessary by C.5.1 above, a custom design for a cathodic protection system including design calculations and analysis is required. It shall include necessary technical specifications, drawings, schedules, and a cost estimate.(#l C.4.3lExcavation and Backfill: The site investigation is not believed to require excavation.(#l C.4.4lSafety: The Contractor shall observe standard electrical work safety requirements. Since the field investigation is limited to nonintrusivetype measurement, the system can remain energized during the investigation. Contractor personnel shall not enter parts of the electrical system or equipment enclosure where energized parts are unprotected by barriers or insulation.(#l ,END OF SECTION  !ԌxW  !SECTION E INSPECTION AND ACCEPTANCE CORROSION INVESTIGATION FOR URD CABLES SPECIFICATION NO. 17103 Rev. 689X C17103EFEDERAL ACQUISITION REGULATIONS (48 CFR CHAPTER 1) CLAUSES E.1.0l52.252.02 Clauses Incorporated by Reference(#l  lThis contract incorporates the following clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.(#l  lREF(  REF NO. %&&h*TITLEX/0X06X6p<X<BXB HXHxNXN TDATE(#  l1. (  52.24604'h*INSPECTION OF SERVICE FIXED PRICEMxNXN TAPR 1984(# ,END OF SECTION  H  C17103FC  SECTION F DELIVERIES AND PERFORMANCE CORROSION INVESTIGATION FOR URD CABLES SPECIFICATION NO. 17103 Rev. 689F.1.0lDELIVERIES(#l  lXl4( hp x (#%'Xl( hp x (#%'a.Delivery point for all draft reports and completed design shall be:(#  lb.The contractor shall be responsible for postage or freight costs incurred when shipping any material to the Government.(# F.2.0l52.25202 Clauses Incorporated by Reference (APR 1984)(#l  lThis contract incorporates the following clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make full text available.(#l  lI.Federal Acquisition Regulation (48 CFR Chapter 1) Clauses.(#  lREF,( REF NO.!&TITLE+0X06X6p<X<BDATE(#  l1.,( 52.21212#&SUSPENSION OF WORK8p<X<BAPRIL 1984(# ,END OF SECTION