WPC 2QBR Z Courierw Roman#|dOed6X@`7@HP LaserJet 4HPLAS4.PRS 4d6X@;\*"P@lr5ddd,Oed6X@`7@s4ddd,鑡d `7r5ddd,d6Nhez7HrV&PƋ΋ߋ~XrAuڋF&&&+=&|I&&+=&|&&-&%ddddddddddddddddddddddddddddddddddddddddNEssEX`AT`````6=`:=`:AATT`BBs``uEssErkkAT`:"`soh`kss`t 4HPLAS4.PRS 4?f\  P6G;\*"P?P2$r 0CourierCourier Bold X` hp x (#%'0*,.8135@8:, P age,  s5  F ooter, B , E dit. Delete the "Project Name (ftr B)" text and replace  s5K it with the name of the project (bolded) . , until you arrive at the document text.(# D.The Guide Specifications are being reviewed and revised. Your technical comments on any guide spec would be greatly appreciated. Also, any specs that are written "from scratch" that would benefit others could be sent to either Dion Dishong or Lori Quayle, RS110.(#  s5  DRAWING DATA REQUIRED: Location and detail drawings as needed, including electrical schematics, wiring diagrams, and equipment list.(#  s4z  REVISIONS OF THIS SECTION:  r5!  CSI format, editorial changes: 2/97 Metric: Technical Update: 2/97 POINT OF CONTACT: Dennis Grevel Phone: (303) 98768580*(( XM s4 #d `7#`X(#FTEMPERATURE CONTROLS Project Name (ftr B)` (#T[2/97] .16908   b-SECTION 16908 )TEMPERATURE CONTROLS PART 1: GENERAL 1.1SUMMARY(# A.Section Includes: [Furnishing] [and] [installing] controls for: heating, ventilating and air conditioning systems.(# B.Related Sections:(# ************************************************** DELETE EITHER 01009 OR 01010. EITHER SECTION 01300 OR 01410 MUST BE USED WHEN 01010 IS USED. ************************************************** Summary of Work`(#MSection 01010 Submittals`(#MSection 01300 Contract Closeout(#`(#MSection 01700 1.3SYSTEM DESCRIPTION A.Requirements: [ .](# 1.4SUBMITTALS(# A.General: Submittals shall be according to [Section 01009 General Information and Requirements.] [Section 01300 - Submittals.] [Section 01365 Certificates of Conformance.](# B.Manufacturer's Literature: Submit [ ] copies of the manufacturer's technical data on the individual control equipment items to be used on this project.(# 1.5QUALITY ASSURANCE(# A.Labeling Requirements: Control devices shall be Underwriters Laboratories, Inc. (UL) listed and labeled. UL listing and labeling will not be required if it can be shown that control devices meet the requirements of another nationally recognized testing laboratory (NRTL).(#  PART 2: PRODUCTS 2.1MATERIALS(# A.General: Control devices shall be constructed of the manufacturer's standard materials, as listed in published product information; types and sizes shall be as indicated or as required for the installation.(# B.Enclosures: Where NEMA numbers are given, it refers to the enclosure type as listed in NEMA 250.(# "0*s's'Ԍ82.2SWITCHES(# A.Time Switch: Shall be [24 hr dial type with day omission feature] [7-day dial type]. Provide switch with an automatically-wound spring mechanism to maintain correct time and operate the contacts for a minimum of 15 hr without power. Provide a manual on-off bypass switch and 30A [SPDT] [DPDT] [3PST] contacts.(# 8 2.3RELAYS(# A.Light Duty Control Relays: Shall be enclosed in transparent plastic enclosures with plug-in terminals on the base. Each relay shall have [DPDT [3PDT] contacts rated 120/240V, 10A continuous. A manual operator shall be included to facilitate circuit testing. Coils shall be [ac] [dc] rated [6] [12] [24] [48] [110] [120] [240] V. Coils shall be rated continuous duty with coil burden not to exceed [5VA inrush, 3VA sealed for ac] [3W for dc]. General-purpose, latching- and time-delay relays shall be available in this general configuration except the time delay relays have contacts rated 5A and have octal-tube type plug-in bases. [Furnish variable [on] [off] time delay range from [.1 to 10 sec] [67 to 600 sec]. Relays shall plug in to socket type bases which have [screw type terminals] [quick-connect type spade lugs] for circuit wire connection. Socket-type bases shall be suitable for individual mounting or for group installation on a section of mounting track.(# B.Industrial-Type Control Relays: Shall be open type, multi-circuit [300V] [600V] industrial-control relays with [2] [4] [8] [12] contacts rated 10A continuous. Contact shall be [convertible] [[ ] N.O. and [ ] N.C.]. Coils shall be for use on [ac and rated [12] [24] [48] [120] [208] [240] [277] [480] [600] V with less than 100VA inrush and 20VA sealed] [dc and rated [12] [24] [48] [64] [125] [250] V with less than 10W burden]. Relays shall be modular type with provision to add on extra contacts to a total of 12; add on a latch attachment and coil clearing contacts; and add on a pneumatic timer attachment for on or off delay of 0.2 sec to 60 sec or add on a transistorized timer attachment for on or off delays of up to 180 sec. Relays shall be arranged for individual or mounting track installation and shall be furnished in open type or NEMA [1] [3R] enclosures. Provide relay with [latch attachment and coil-clearing contacts] [pneumatic timer for [on] [off] delay] [transistorized timer for [on] [off] delay].(# 2.4THERMOSTATS(# ***************************************************** Thermostats for HVAC applications are normally specified in Division 15. ***************************************************** A.General: Shall have guards to enclose and protect the thermostat against tampering and unauthorized adjustments of setting. Subbases for manual system switching shall suit the application. Thermostats for switching electric heat loads directly shall include a definite off position. Adjustable anticipators shall be included on low-voltage thermostats used for comfort control of space temperature. Battery or other emergency back-up shall be provided for clock or program-type thermostats.(# B.Line Voltage Thermostats: Shall be [light-duty type with contacts rated 4A at 240V or 8A at 120V] [heavy-duty type with contacts rated 8A at 120V and 16A at 120V] for control of fan coils, fans, motor starters, valves, or contactors. For resistive loads only, the}&0*s's' light-duty type shall be rated 7A and the heavy-duty type 22A at 120 or 240V. Switching shall be [SPDT] [2 SPDT]. Application shall be [heating-cooling] [2-stage heating or 2-stage cooling] [1-stage heating-cooling] [ ]. Set-point shall be adjustable from [56 to 94 degrees F] [46 to 84 degrees F] [ ]. Differential shall be [1 degree F] [2 degrees F] [3 degrees F] [ ].(# C.Low Voltage Thermostats: Shall include [1] [2] [SPST] [SPDT] contacts rated [0.8] [1.5] A at 30V. Shall have a set-point range of [45 to 90 degrees F] [ ] [Shall include a positive off] [Adjustable, tamper resistant, temperature stops are required]. Thermostats shall be suitable for control of [heating] [cooling] [both heating and cooling] systems.(# D.Clock Thermostats: Shall include [dial] [color-coded plug-in pins] to set an adjustable program to automatically lower and raise the temperature control point for [one] [ ] periods in every 24 hr. Pickup and setback times need only be set once for continuous operation of the system. Temperature setting range is [54 to 86 degrees F] [40 to 90 degrees F] [ ]. Contacts are SPDT rated 1.5A at 30V. Application is for [heating] [cooling] [heating and cooling].(# E.Solid-State, Programmable Thermostats: Shall allow full 7-day scheduling; multiple offset periods with mode indicator; program override, advance and skip keys; clock LED readout; temperature indicator; two stages of heat and cool-control capability; temperature setting range 50 to 86 degrees F for heat and 54 to 90 degrees F for cool; and contact rating 1.0A.  PART 3: EXECUTION 3.1INSTALLATION A.General: Install control devices as indicated, complying with the manufacturer's written instructions, applicable requirements of codes and standards, and according to recognized industry practices.(# 3.2TRAINING OF GOVERNMENT EMPLOYEES A.Requirements: See Section 01700 - Contract Closeout.(#  -PART 4: MEASUREMENT AND PAYMENT ***************************************************** WHEN A "LUMP SUM" CONTRACT IS USED, DELETE THE TITLE PART 4: MEASUREMENT AND PAYMENT, AND BOTH ARTICLES FROM THIS SECTION. MEASUREMENT AND PAYMENT WILL BE ADDRESSED IN PART 4 OF SECTION 01010 SUMMARY OF WORK. ***************************************************** 4.1METHOD OF MEASUREMENT A.Units: The work described in this section will not be measured for payment. - 4.2BASIS OF PAYMENT A.Payment: No direct payment for the work described under this section will be made. Consideration for this item shall be included in the bid price for other items of the Contract.(# 0,END OF SECTION