WPC 2QBR Z Courierw Roman#|dOed6X@`7@HP LaserJet 4HPLAS4.PRS 4d6X@;\*"P@lr5ddd,Oed6X@`7@s4ddd,鑡d `7r5ddd,d6Nhez7HF6裷p=^Y[Xð6SQV&t18 <t &:uCF&? t &?.tddddddddddddddddddddddddddddddddddddddddNEssEX`AT`````6=`:=`:AATT`BBs``uEssErkkAT`:"`soh`kss`t 4HPLAS4.PRS 4?f\  P6G;\*"P?P2$r 0CourierCourier Bold X` hp x (#%'0*,.8135@8:, P age,  s5  F ooter, B , E dit. Delete the "Project Name (ftr B)" text and replace  s5 it with the name of the project (bolded) . , until you arrive at the document text.(# D.The Guide Specifications are being reviewed and revised. Your technical comments on any guide spec would be greatly appreciated. Also, any specs that are written "from scratch" that would benefit others could be sent to either Dion Dishong or Lori Quayle, RS110.(#  s5  DRAWING DATA REQUIRED: Location and detail drawings as needed, including electrical schematics, wiring diagrams, and equipment list.(#  s4  REVISIONS OF THIS SECTION:  r5z  CSI format, editorial changes: 2/97 Metric: Technical Update: 2/97 POINT OF CONTACT: Dennis Grevel Phone: (303) 9876858o0*(( XM s4 #d `7#`(#BELECTRIC RADIANT HEATERS Project Name (ftr B)` (#T[2/97] .16904   b-SECTION 16904 <'ELECTRIC RADIANT HEATERS PART 1: GENERAL 1.1SUMMARY A.Section Includes: [Furnishing] [and] [installing] ceiling panel radiant type electric heaters and infrared electric heaters.(# B.Related Sections:(# ************************************************** DELETE EITHER 01009 OR 01010. EITHER SECTION 01300 OR 01410 MUST BE USED WHEN 01010 IS USED. ************************************************** Summary of Work`(#MSection 01010 Submittals`(#MSection 01300 Contract Temperature Closeout`(#MSection 01700 Electric Temperature Control Systems`(#MSection 15975 1.2SYSTEM DESCRIPTION A.Requirements: [ .](# 1.3SUBMITTALS A.General: Submittals shall be according to [Section 01009 General Information and Requirements. [Section 01300 - Submittals.] [Section 01365 Certificates of Conformance.](# B.Manufacturer's Literature: Submit [ ] copies of the manufacturer's technical data on the electric radiant heaters to be used on this project.(# 1.4QUALITY ASSURANCE A.Labeling Requirements: Electric radiant heaters shall be Underwriters Laboratories, Inc. (UL) listed and labeled. UL listing and labeling will not be required if it can be shown that heaters meet the requirements of another nationally recognized testing laboratory (NRTL).(#  PART 2: PRODUCTS 2.1MATERIALS A.General: Heaters shall be constructed of the manufacturer's standard materials, as listed in published product information; types and sizes shall be as indicated or as required for the installation.(# B.Acoustic Requirements: Quiet operation of the heating system is required. Noisy thermal expansion and contraction, loud relay clicking or alternating current hum will be cause for rejection of individual heaters or the entire system. The Contracting Officer will determine if the noise level is objectionable.(# /%0*s's'Ԍ2.2CEILING PANEL RADIANT HEATERS A.Thermal Requirements: Each heater shall produce its rated heat output in watts at an impressed voltage of [120/240] [208] [277] volts. It shall provide radiated heat without air movement. (# B.Construction: Heater size shall be [2 ft x 2 ft] [2 ft x 4 ft] panel for mounting on T-bar grid. Accessory kits for [surface] [recess] mounting are required. Heating element to be electrically resistive graphite sandwiched between two layers of insulation. This element with 1-1/2 inches of fiberglass insulation on top shall be enclosed in a zinc-coated steel housing. Heater unit shall include a 40-inch flexible conduit with conductors and fitting for connection to supply circuit.(# C.Control: [ ].(# 2.3INFRARED HEATERS A.Thermal Requirements: Each heater shall produce its rated heat output in watts at an impressed voltage of [208] [240/480] [277] volts. It shall provide radiated heat without air movement.(# B.Construction: Heater shall be suitable for indoor or outdoor use. It shall include an anodized aluminum reflector with a [90-degree symmetrical broad distribution pattern] [60-degree symmetrical medium distribution pattern] [30-degree symmetrical narrow distribution pattern] [30-degree] [60-degree] [asymmetrical perimeter distribution pattern]. Heater shall be [surface mounted] [conduit mounted] [chain suspended]. [Single] [Double] heating element shall be [metal sheath] [quartz tube] [quartz lamp] type. Heater shall be 4 inches deep by 10 inches wide by [26] [36] [48] inches long. (# C.Control: Heater shall be controlled from a local toggle switch of the correct rating.(#  PART 3: EXECUTION 3.1INSTALLATION A.General: Install heaters as indicated, complying with the manufacturer's written instructions, applicable requirements of codes and standards, and according to recognized industry practices.(# 3.2TRAINING OF GOVERNMENT EMPLOYEES A.Requirements: See Section 01700 - Contract Closeout.(#  PART 4: MEASUREMENT AND PAYMENT ***************************************************** WHEN A "LUMP SUM" CONTRACT IS USED, DELETE THE TITLE PART 4: MEASUREMENT AND PAYMENT, AND BOTH ARTICLES FROM THIS SECTION. MEASUREMENT AND PAYMENT WILL BE ADDRESSED IN PART 4 OF SECTION 01010 SUMMARY OF WORK. ***************************************************** 4.1METHOD OF MEASUREMENT A.Units: The work described in this section will not be measured for payment.(# %0*s's'ԌC4.2BASIS OF PAYMENT A.Payment: No direct payment for the work described under this section will be made. Consideration for this item shall be included in the Cbid price for other items of the Contract.(# 0,END OF SECTION