WPC 2QBR Z Courierw Roman#|dOed6X@`7@HP LaserJet 4HPLAS4.PRS 4d6X@;\*"P@lr5ddd,Oed6X@`7@s4ddd,鑡d `7r5ddd,d6Nhez7H6r  dyyj- Rx&.PRS ddddddddddddddddddddddddddddddddddddddddNEssEX`AT`````6=`:=`:AATT`BBs``uEssErkkAT`:"`soh`kss`t 4HPLAS4.PRS 4?f\  P6G;\*"P?P2$r 0CourierCourier Bold X` hp x (#%'0*,.8135@8:, P age,  s5  F ooter, B , E dit. Delete the "Project Name (ftr B)" text and replace  s5 it with the name of the project (bolded) . , until you arrive at the document text.(# D.The Guide Specifications are being reviewed and revised. Your technical comments on any guide spec would be greatly appreciated. Also, any specs that are written "from scratch" that would benefit others could be sent to either Dion Dishong or Lori Quayle, RS110.(#  s5  DRAWING DATA REQUIRED: Location and detail drawings as needed, including electrical schematics, wiring diagrams, and equipment list.(#  s4  REVISIONS OF THIS SECTION:  r5z  CSI format, editorial changes: 2/97 Metric: Technical Update: 2/97 POINT OF CONTACT: Dennis Grevel Phone: (303) 9876858o0*(( XM s4 #d `7#`(#GELECTRIC CONVECTORS Project Name (ftr B)` (#T[2/97] .16901   b-SECTION 16901 6*ELECTRIC CONVECTORS PART 1: GENERAL 1.1SUMMARY(# A.Section Includes: [Furnishing] [and] [installing] convection type electric heaters, plus integral safety and control devices.(# B.Related Sections:(# ************************************************** DELETE EITHER 01009 OR 01010. EITHER SECTION 01300 OR 01410 MUST BE USED WHEN 01010 IS USED. ************************************************** Summary of Work`(#MSection 01010 Submittals`(#MSection 01300 Contract Closeout`(#MSection 01700 Electric Temperature Control Systems`(#MSection 15975 1.2SYSTEM DESCRIPTION(# A.Requirements: [ .](# 1.3SUBMITTALS(# A.General: Submittals shall be according to [Section 01009 General Information and Requirements.] [Section 01300 - Submittals.] [Section 01365 Certificates of Conformance.](# B.Manufacturer's Literature: Submit [ ] copies of the manufacturer's technical data on each type of baseboard heater to be furnished on this project.(# 1.4QUALITY ASSURANCE(# A.Labeling Requirements: Electric convector heaters shall be Underwriters Laboratories, Inc. (UL) listed and labeled. UL listing and labeling will not be required if it can be shown that heaters meet the requirements of another nationally recognized testing laboratory (NRTL).(#  PART 2: PRODUCTS 2.1MATERIALS(# A.General: Heaters shall be constructed of the manufacturer's standard materials, as listed in published product information; types and sizes shall be as indicated or as required for the installation.(# B.Acoustic Requirements: Quiet operation of the heating system is required. Noisy thermal expansion and contraction, loud relay clicking, or alternating current hum will be cause for rejection of individual heaters or the entire system. Decision as to if the noise level is objectionable will be made by the Contracting Officer.(# /%0*s's'Ԍ2.2CABINET CONVECTORS(# A.Thermal Requirements: Each heater shall be capable of producing [1] [2] [3] or [4] kW of heat at [208] [240] [277] volts. Each heater shall include a line voltage thermal limit switch with automatic reset to protect from overheating.(# B.Enclosure: Enclosure shall be 16-ga, tamper-resistant, cabinet with louvers which restrict entry of foreign objects. Interior baffles shall be provided to direct cool air over front covers. Width shall be [24] [36] [48] inches. Unit shall be designed for [surface] [recessed] mounting [directly on the floor] [above the floor].(# C.Control: Options shall include an integral [manually operated, 20 amp, 277-V, disconnect switch] [SPST, 55 to 85 degrees F adjustable range thermostat with definite off position] [SPDT, 20 amp, 277-V, power circuit relay with [120-V] [24-V] coil].(#  PART 3: EXECUTION 3.1INSTALLATION(# A.General: Install heaters as indicated, complying with the manufacturer's written instructions, applicable requirements of codes and standards, and according to recognized industry practices.(# 3.2TRAINING OF GOVERNMENT EMPLOYEES(# A.Requirements: See Section 01700 - Contract Closeout.(#  PART 4: MEASUREMENT AND PAYMENT ***************************************************** WHEN A "LUMP SUM" CONTRACT IS USED, DELETE THE TITLE PART 4: MEASUREMENT AND PAYMENT, AND BOTH ARTICLES FROM THIS SECTION. MEASUREMENT AND PAYMENT WILL BE ADDRESSED IN PART 4 OF SECTION 01010 SUMMARY OF WORK. ***************************************************** 4.1METHOD OF MEASUREMENT(# A.Units: The work described in this section will not be measured for payment.(# 4.2BASIS OF PAYMENT(# A.Payment: No direct payment for the work described under this section will be made. Consideration for this item shall be included in the bid price for other items of the Contract.(# 0,END OF SECTION