WPC 2QBR Z Courierw Roman#|dOed6X@`7@HP LaserJet 4HPLAS4.PRS 4d6X@;\*"P@lr5ddd,Oed6X@`7@s4ddd,鑡d `7r5ddd,d6Nhez7Hega CG Omega BoldCG Omega Bold ItalicCG Omega ItalicClarendon Condensed BoldGaddddddddddddddddddddddddddddddddddddddddNEssEX`AT`````6=`:=`:AATT`BBs``uEssErkkAT`:"`soh`kss`t 4HPLAS4.PRS 4?f\  P6G;\*"P?P2$r 0CourierCourier Bold X` hp x (#%'0*,.8135@8:, P age,  s5  F ooter, B , E dit. Delete the "Project Name (ftr B)" text and replace  s5K it with the name of the project (bolded) . , until you arrive at the document text.(# D.The Guide Specifications are being reviewed and revised. Your technical comments on any guide spec would be greatly appreciated. Also, any specs that are written "from scratch" that would benefit others could be sent to either Dion Dishong or Lori Quayle, RS110.(#  s5  DRAWING DATA REQUIRED: Location and detail drawings as needed, showing riser diagrams and plans as appropriate.(#  s4z  REVISIONS OF THIS SECTION:  r5!  CSI format, editorial changes: 2/97 Metric: Technical Update: 2/97 POINT OF CONTACT: Dennis Grevel Phone: (303) 98768580*(( XM s4 #d `7#`p(#<TELEPHONE DISTRIBUTION SYSTEMS Project Name (ftr B)` (#T[2/97] .16741   b-SECTION 16741 $TELEPHONE DISTRIBUTION SYSTEMS PART 1: GENERAL 1.1SUMMARY(# A.Section Includes: [Furnishing] [and] [installing] a low-voltage, premises wiring system for [telephone] [and] [data] distribution.(# B.Related Sections:(# ************************************************** DELETE EITHER 01009 OR 01010. EITHER SECTION 01300 OR 01410 MUST BE USED WHEN 01010 IS USED. ************************************************** Summary of Work&+049``>@@CSection 01010 Submittals !&+049``>@@CSection 01300 Contract Closeout&+049``>@@CSection 01700 1.2SYSTEM DESCRIPTION(# A.General: The telephone distribution system shall include the telephone backboard, terminal blocks, conduit, conductors, wiring devices, and all other items (except for handsets and associated wires) necessary to connect to the telephone company service.(# 1.3SUBMITTALS(# A.General: Submittals shall be according to [Section 01009 General Information and Requirements.] [Section 01300 - Submittals.] [Section 01365 Certificates of Conformance.](# B.Manufacturer's Literature: Submit [ ] copies of the manufacturer's descriptive data for the following items to be used on this project:(# 1.` ` Conductors(#` 2.` ` Wiring Devices(#` 3.` ` Schematics(#` 1.4QUALITY ASSURANCE(# A.Labeling Requirements: Telephone distribution system components shall be Underwriters Laboratories, Inc. (UL) listed and labeled. UL listing and labeling will not be required if it can be shown that system components meet the requirements of another nationally recognized testing laboratory (NRTL).(#  PART 2: PRODUCTS 2.1MATERIALS(# A.General: Telephone distribution system components shall be constructed of the manufacturer's standard materials, as listed in published product information; types and sizes shall be as indicated or as required for the installation.(# 2.2EQUIPMENT(# %0*s's'ԌA.Terminal Board: Shall be 3/4inch plywood, [4'x8'] [_'x_'], minimum. Provide 100 pair KATT IDC block with 24 KATT4 connectors and ring runs for cable distribution.(# B.Cable: Shall be Category 5, 4pair, 24 AWG, solid copper, unshielded twisted pair. All telephone (voice) cable shall be one color; all data cable shall be one color, different from voice cable color. Cable installed in plenums shall be listed for such use.(# ***************************************************** ADD ADDITIONAL DEVICES AS NEEDED. (LIST AND DESCRIBE ANY ADDITIONAL SENSORS SUCH AS CAPACITANCE, AUDIO, VIBRATION, INDOOR MICROWAVE, AND ULTRASONIC DETECTORS.) ***************************************************** C.Wiring Devices: Shall have a single gang bezel suitable for mounting three modules. Telephone module shall be a two position 4conductor USOC jack, with KATT connector. Data module shall be a two position EIA 568A jack, with KATT connector. A blank module shall be installed at unused locations.(# D.Power Pole Outlets: Shall be a two module surface block.(#  PART 3: EXECUTION 3.1INSTALLATION(# A.General: Install telephone distribution equipment as indicated, complying with manufacturer's written instructions, applicable requirements of codes and standards, and according to recognized industry practices.(# B.Mounting: Mount telephone distribution equipment where shown on the drawings. The telephone terminal board shall be screwed to the wall with 1/2inch standoffs, using mounting method described in Section 16072 Supporting Devices. (# C.Distribution: Each cable drop shall consist of two separate cable runs, one voice cable run and one data cable run. The cable drops shall originate at the patch panels in the telecommunications hub closet [on each floor] and terminate at station jacks located throughout the floor as shown on the drawings. Spare cables shall originate at the patch panels in the telecommunication hub closet [on each floor] and shall be terminated with an RJ45 jack and have 50 feet of cable coiled in a 24 inch diameter loop attached to the cable support system at locations shown on the drawings. Where loose cables enter conduits or power poles, cables shall have at least one loop (24 inch min. diameter) secured with a cable tie.(# 3.2ADJUSTING(# A.Requirements: Alarm equipment shall be adjusted by the Contractor according to the manufacturer's written instructions.(# 3.3DEMONSTRATION(# A.Requirements: In addition to system testing, each detector and alarm shall be tested by the Contractor to insure its correct operation. Malfunctioning units shall be corrected and retested by the Contractor to demonstrate compliance with the specifications.(# }&0*s's'Ԍ3.4TRAINING OF GOVERNMENT EMPLOYEES(# A.Requirements: See Section 01700 Contract Closeout.(#  PART 4: MEASUREMENT AND PAYMENT ***************************************************** WHEN A "LUMP SUM" CONTRACT IS USED, DELETE THE TITLE PART 4: MEASUREMENT AND PAYMENT, AND BOTH ARTICLES FROM THIS SECTION. MEASUREMENT AND PAYMENT WILL BE ADDRESSED IN PART 4 OF SECTION 01010 SUMMARY OF WORK. ***************************************************** 4.1METHOD OF MEASUREMENT(# A.Units: The work described in this section will not be measured for payment.(# 4.2BASIS OF PAYMENT(# A.Payment: No direct payment for the work described under this section will be made. Consideration for this item shall be included in the bid price for other items of the Contract.(# 0,END OF SECTION