WPC 2QBR Z Courierw Roman3|dOed6X@`7@HP LaserJet 4HPLAS4.PRS 4d6X@;\*"P@lr5ddd,Oed6X@`7@s4ddd,鑡d `7r5ddd,d6Nhez7Hfiles\gsoption 9NREMOVE THIS OUTLINE ddddddddddddddddddddddddddddddddddddddddNEssEX`AT`````6=`:=`:AATT`BBs``uEssErkkAT`:"`soh`kss`t 4HPLAS4.PRS 4?f\  P6G;\*"P?P2$r 0CourierCourier Bold X` hp x (#%'0*,.8135@8:, P age,  s5  F ooter, B , E dit. Delete the "Project Name (ftr B)" text and replace  s5K it with the name of the project (bolded) . , until you arrive at the document text.(# D.The Guide Specifications are being reviewed and revised. Your technical comments on any guide spec would be greatly appreciated. Also, any specs that are written "from scratch" that would benefit others could be sent to either Dion Dishong or Lori Quayle, RS110.(#  s5  DRAWING DATA REQUIRED: Location and detail drawings as needed. K.3.1D: Select applicable conditions.(# L.4.1 and 4.2: When a "lump sum" Contract is used, delete the title PART 4: MEASUREMENT AND PAYMENT, and both articles from this section. Measurement and payment will be addressed in Part 4 of Section 01010 Summary of Work.(#  s4  REVISIONS OF THIS SECTION:  r5Y  CSI format, editorial changes: 2/97 Metric: Technical Update: 2/97 POINT OF CONTACT: Dennis Grevel Phone: (303) 9876858N!0*(( XM s4 #d `7#`(#GINTERIOR LUMINAIRES Project Name (ftr B)` (#T[2/97] .16510   h*SECTION 1651016510 6*INTERIOR LUMINAIRES   b-SECTION 16510 6*INTERIOR LUMINAIRES PART 1: GENERAL 1.1SUMMARY: A.Section Includes: [Furnishing] [and] [installing] interior luminaires (lighting fixtures), ballasts, and lamps. The "type" letter used for reference to various fixtures corresponds to the alphabetical letter used to identify fixtures on the drawings.(# B.Related Sections:(# ************************************************** DELETE EITHER 01009 OR 01010. EITHER SECTION 01300 OR 01410 MUST BE USED WHEN 01010 IS USED. ************************************************** Summary of Work`(#MSection 01010 Submittals`(#MSection 01300 Acoustical Suspension Systems`(#MSection 09130 Gypsum Board Systems`(#MSection 09260 1.2DEFINITIONS: A.Lighting Fixture Mounting Height: The distance from the floor to the following points:(# 1.` ` For Wall Mounting: To the center of the outlet box.(#` 2.` ` For Suspension Mounting: To the lowest point on the fixture.(#` 1.3SUBMITTALS: A.General: Submittals shall be according to [Section 01009 General Information and Requirements.] [Section 01300 - Submittals.] [Section 01365 Certificates of Conformance.](# B.Manufacturer's Literature: Submit [ ] copies of the manufacturer's technical data for the light fixtures to be used on this project.(# C.Photometric Data: Submit [ ] copies of light distribution (batwing) curves, coefficient of utilization tables and manufacturer's recommended spacing/mounting height data for all lighting fixtures [except the following:(# 1.` ` Type [ ](#` 2.` ` Type [ ](#` D.Shop Drawings: Submit [ ] copies of shop drawings for the lighting fixtures to be used on this project showing dimensions, construction details, installation details, accessories, and, where applicable, suspension and lowering mechanisms, for the following lighting fixtures:(# 1.` ` Type [ ](#` 2.` ` Type [ ](#` 1.4QUALITY ASSURANCE:}&0*s's'ԌA.Labeling Requirements: Lighting fixtures and ballasts shall be Underwriters Laboratories, Inc. (UL) listed and labeled. Fluorescent ballasts shall be CBM/ETL labeled. UL listing and labeling will not be required if it can be shown that fixtures and ballasts meet the requirements of another nationally recognized testing laboratory (NRTL).(#  PART 2: PRODUCTS 2.1MATERIALS: A.General: Lighting fixtures and accessories shall be constructed of the manufacturer's standard materials, as listed in published product information; types and sizes shall be as indicated or as required for the installation.(# B.Lamp Requirements: Lighting fixtures shall be furnished complete with lamps of the quantity and type specified. (# C.Photometrics: Shall be the published certified results of tests by an independent photometric testing laboratory.(# D.Lighting Fixture Supports: See Section 16072 Supporting Devices.(# E.Lamp Wattage Label: Each incandescent fixture shall be indelibly stamped or labeled to show the manufacturers' restriction on the largest wattage of lamp permissible.(# *****************************************************  s5 BELOW FIVE PARAS ARE EXAMPLES ONLY. EDIT TO SUIT PROJECT . ***************************************************** F.Incandescent Fixtures: Shall be as follows:(# 1.` ` Type G Lighting Fixture: Shall be recessed, 12 inches (nominal diameter) round with polished reflector, Fresnel glass lens, and white finished trim frame suitable for installation in a gypsum board ceiling in spaces where clearance above ceiling is not more than 6 inches. Fixture shall be equipped with a side mounted pre-wired junction box UL listed for through branch circuit wiring. Fixture shall be rated 150 watts (minimum), 120V and shall be lamped with one 100 watt, A21 lamp. (#` G.Fluorescent Fixtures: Shall be as follows:(# 1.` ` General: Unless otherwise specified, body, reflectors, wiring cover, end caps, door frame, hinges and latches shall be steel, not less than 24 ga for wiring cover and 22 ga for all other parts. Body and reflectors shall be die formed and shall have embossed ribs or flanges for rigidity. Doors shall seal when closed to prevent peripheral light leaks. Steel parts shall be pretreated with a multi-stage, phosphate (or other similar) under-finish to enhance paint adhesion and corrosion resistance. Steel parts shall be finished white with a high gloss baked enamel or baked dry polyester powder coating of 85% (minimum) reflectance.(#` 2.` ` Ballast: Unless otherwise specified, ballasts shall be rapid start, high power factor, Class P with A sound rating and catalog-listed by the manufacturer as energy saving type.(#` 3.` ` Type A Lighting Fixture: Shall be a 2 x 4 foot recessed troffer with prismatic lens in steel framed door with hinges and latches. Lens shall be 100% virgin acrylic; overall thickness not less than 120 mils; unpenetrated thickness (thickness between the base of~&0*s's' the prisms and the flat surface) shall be not less than 50 mils. Fixture shall be suitable for installation in a lay-in, suspended ceiling. Ballast shall be suitable for 120 V, 60 hz power supply. Fixture shall be lamped with two energy saving (35 watt max), 3,000 lumen (minimum initial output) lamps. (#` H.H-I-D Fixtures: Shall be as follows:(# 1.` ` Type K Lighting Fixture: Shall be designed and equipped with an integral, prewired ballast to operate on a 120 V, 60 hz power supply. The ballast shall be designed to limit the starting current to an amount not to exceed normal operating current. Ballast shall be capable of starting and operating from 110 to -20 degreeF. The fixture shall consist of two major assemblies, the ballast housing assembly and the reflector/lens assembly. The two assemblies shall be equipped with positive vibration-proof latching mechanisms so that the two assemblies can be easily disconnected from each other in the field. The lens of the reflector/lens assembly shall be equipped with hinge and latch for easy access to the lamp. Fixture shall include a 250 watt high pressure sodium lamp. (#` I.Special Purpose Lighting Fixtures: Shall be as follows:(# 1.` ` Type X Lighting Fixture: Shall be a recessed wall mounted exit fixture consisting of a recessed 18 ga (minimum) steel box, approximately 12 inches wide by 9 inches high by 4 inches deep and a face assembly. The face assembly shall consist of a metal plate with stencilled arrows and letters approximately 6 inches high and 3/4 inch wide. Face plate shall be backed by a red, translucent plastic back plate of the same size. Stencil and back plates shall be retained and attached to the box by a peripheral metal trim frame. Illumination shall be provided by two 120V, T-6-1/2, double contact bayonet base, and incandescent lamps with 50,000 hr rated life. Lamps using diodes, transformers or other power altering devices to reach specified rated life shall be replaced. (#`  PART 3: EXECUTION 3.1INSTALLATION A.General: Install lighting fixtures and accessories as indicated, complying with the manufacturer's written instructions, applicable requirements of codes and standards, and according to recognized industry practices.(# B.Alignment: Where lighting fixtures are shown on the drawings to be in line in any direction, locate them carefully so that they will be aligned with building features and with each other.(# C.Suspended Lighting Fixtures: Hang as follows:(# 1.` ` Use suspension kits consisting of swivel, canopy and stem to hang fixtures which are to be suspended in finished space.(#` 2.` ` Where fixtures are to be stem mounted in unfinished space, use a combination swivel box cover with threaded conduit at the upper end of a conduit stem.(#` 3.` ` Where chain-suspended fluorescent fixtures are indicated, use a box cover with chain hooks and receptacle to hang the fixture from the outlet box. Attach the "Y" yoke end of the chain to the top corners at each end of the fixture in a manner guaranteed not to come loose due to vibration or bumping. Connect the fixture to%0*s's' the box cover receptacle with a cord set. Tie the cord to a supporting chain at 18-inch intervals.(#` D.Lay-In Fluorescent Fixtures in Suspended T-Bar Ceilings: Shall be as follows:(# 1.` ` Install a 6-foot length of flexible conduit between an outlet box in the conduit system and the fixture to enclose the branch circuit conductors.(#` 2.` ` In seismic zone No. 4 (per Uniform Building Code), support the fixtures independent of the T-bar support by installing chain supports as specified for chain-suspended fixture.(#` E.Lamping: Install specified lamps in lighting fixtures.(# 3.2CLEANING A.Requirements: When dust, dirt, grime or adhesives (other than name or data labels) exists on lamps, lenses, reflectors or exposed parts, remove with soft cloth and mild suds and rinse clean.(#  PART 4: MEASUREMENT AND PAYMENT 4.1METHOD OF MEASUREMENT A.Units: The work described in this section will not be measured for payment.(# 4.2BASIS OF PAYMENT A.Payment: No direct payment for the work described under this section will be made. Consideration for this item shall be included in the bid price for other items of the Contract.(# 0,END OF SECTIONŃ