WPC 2QBR Z Courierw Roman#|dOed6X@`7@HP LaserJet 4HPLAS4.PRS 4d6X@;\*"P@lr5ddd,Oed6X@`7@s4ddd,鑡d `7r5ddd,d6Nhez7H USED WHEN 01010 IS USED. ***************ddddddddddddddddddddddddddddddddddddddddNEssEX`AT`````6=`:=`:AATT`BBs``uEssErkkAT`:"`soh`kss`t 4HPLAS4.PRS 4?f\  P6G;\*"P?P2$r 0CourierCourier Bold X` hp x (#%'0*,.8135@8:, P age,  s5  F ooter, B , E dit. Delete the "Project Name (ftr B)" text and replace  s5 it with the name of the project (bolded) . , until you arrive at the document text.(# D.The Guide Specifications are being reviewed and revised. Your technical comments on any guide spec would be greatly appreciated. Also, any specs that are written "from scratch" that would benefit others could be sent to either Dion Dishong or Lori Quayle, RS110.(#  s5  DRAWING DATA REQUIRED: Location and detail drawings as needed.  s4,  REVISIONS OF THIS SECTION:  r5  CSI format, editorial changes: 2/97 Metric: Technical Update: 2/97 POINT OF CONTACT: Dennis Grevel Phone: (303) 98768580*(( OXM s4 #d `7#`(#OPANELBOARDS Project Name (ftr B)` (#T[2/97] .16442   b-SECTION 16442 .PANELBOARDS PART 1: GENERAL 1.1SUMMARY A.Section Includes: [Furnishing] [and] [installing] panelboards.(# B.Related Sections:(# ************************************************** DELETE EITHER 01009 OR 01010. EITHER SECTION 01300 OR 01410 MUST BE USED WHEN 01010 IS USED. ************************************************** Summary of Work`(#MSection 01010 Submittals`(#MSection 01300 1.2SUBMITTALS A.General: Submittals shall be according to [Section 01009 General Information and Requirements.] [Section 01300 Submittals.] [Section 01365 Certificates of Conformance.](# B.Manufacturer's Literature: Submit [ ] copies of the manufacturer's technical data for the panelboards to be used on this project. (# C.Shop Drawings: Submit [ ] copies of shop drawings for the power distribution and motor control panelboards to be used on this project. The shop drawings shall indicate dimensions for panelboard installations. Show layout, mountings, and supports where applicable.(# 1.3QUALITY ASSURANCE A.Labeling Requirements: Panelboards shall be Underwriters Laboratories, Inc. (UL) listed and labeled. UL listing and labeling will not be required if it can be shown that panelboards meet the requirements of another nationally recognized testing laboratory (NRTL).(#  PART 2: PRODUCTS 2.1MATERIALS A.General: Panelboards shall be constructed of the manufacturer's standard materials, as listed in published product information; types and sizes shall be as indicated or as required for the installation.(# B.Service Entrance Panelboards: Shall be UL listed for such use.(# C.Panelboard Enclosure: Shall be designed for wall mounting and shall be dead front with boxes, fronts, and doors.(# D.Buses: Shall be copper. Neutral bus shall be full size (same rating as phase buses) and insulated from the cabinet.(# E.Main Breaker Location: Operating handle for the main breaker shall be on the vertical centerline of the panelboard front.(# }&0*s's'ԌF.Lineside Lugs: On the buses or main breaker shall be suitable for either copper or aluminum panelboard feeder.(# G.Circuit Breakers: Shall be as required in Section 16411 - Circuit Breakers.(# H.Breaker Connection to Bus Bars: Shall be sequence phase, [bolt on] [plug in] type, unless otherwise indicated.(# I.Provisions for Future Additions: Where "space" or other indication that space for future installation of circuit breakers is noted on the drawings, the space shall be equipped with bus jumpers, tabs, insulating shields, and any other connection material equal to that provided for breakers installed at the factory.(# J.Branch Circuit and Appliance Panelboards: Shall be [Type I, Class 1] [Type I, Class 2 (loadcenter)] as defined in Fed. Spec. W-P 115B.(# K.Power Distribution Panelboards: Shall be Type I, Class 1 as defined in Fed. Spec. W-P-115B.(# L.Motor Control Panelboards: Shall consist of main, feeder and branch circuit breakers, and combination circuit breaker/motor starters as shown on panelboard schedules on the drawings. The motor starter and associated circuit breaker feeding a motor circuit shall be mounted immediately adjacent to each other in the panelboard.(# M.Motor Starters: Shall be as required in Section 16421 - Motor Starters, including requirements for control circuit devices and indicator lights.(#  PART 3: EXECUTION 3.1INSTALLATION A.General: Install panelboards as indicated, complying with the manufacturer's written instructions, applicable requirements of codes and standards, and according to recognized industry practices.(# B.Panelboard Mounting: [Shall be surface mounted.] [Unless otherwise indicated, install lighting and appliance branch circuit panelboards recessed and power distribution and motor control panelboards on surface.](# C.Mounting Height: As specified for cabinets in Section 16138 - Cabinets and Enclosures.(# D.Breaker and Circuit Numbering: Install circuit breakers in the exact arrangement shown on the panelboard configurations. Number circuit breakers and connect home run circuit conductors to circuit breakers according to numbering shown on the drawings.(# E.Conductor Bundling: As required in Section 16120 - Conductors and Cables.(# F.Connections: Prior to final inspection, the Contractor shall check the breaker-to-bus and breaker-to-conductor connections to ensure that all are tight.(# %0*s's'ԌG.Directory: The Contractor shall fill out the panelboard directory with typewritten information that states precisely which outlets or equipment are supplied by each circuit breaker.(# H.Preparation for Final Inspection: The Contractor shall vacuum clean inside of panelboard enclosures. Leave panelboard fronts off of panelboard prior to final inspection. Install fronts after the final inspection has been completed.(#  PART 4: MEASUREMENT AND PAYMENT ***************************************************** WHEN A "LUMP SUM" CONTRACT IS USED, DELETE THE TITLE PART 4: MEASUREMENT AND PAYMENT, AND BOTH ARTICLES FROM THIS SECTION. MEASUREMENT AND PAYMENT WILL BE ADDRESSED IN PART 4 OF SECTION 01010 SUMMARY OF WORK. ***************************************************** 4.1METHOD OF MEASUREMENT A.Units: The work described in this section will not be measured for payment.(# 4.2BASIS OF PAYMENT A.Payment: No direct payment for the work described under this section will be made. Consideration for this item shall be included in the bid price for other items of the Contract.(# 0,END OF SECTION