WPC 2QBR Z Courierw Roman#|dOed6X@`7@HP LaserJet 4HPLAS4.PRS 4d6X@;\*"P@lr5ddd,Oed6X@`7@s4ddd,鑡d `7r5ddd,d6Nhez7HЊXddddddddddddddddddddddddddddddddddddddddNEssEX`AT`````6=`:=`:AATT`BBs``uEssErkkAT`:"`soh`kss`t 4HPLAS4.PRS 4?f\  P6G;\*"P?P2$r 0CourierCourier Bold X` hp x (#%'0*,.8135@8:, P age,  s5  F ooter, B , E dit. Delete the "Project Name (ftr B)" text and replace  s5 it with the name of the project (bolded) . , until you arrive at the document text.(# D.The Guide Specifications are being reviewed and revised. Your technical comments on any guide spec would be greatly appreciated. Also, any specs that are written "from scratch" that would benefit others could be sent to either Dion Dishong or Lori Quayle, RS110.(#  s5  DRAWING DATA REQUIRED: Location and detail drawings as needed.  s4,  REVISIONS OF THIS SECTION:  r5  CSI format, editorial changes: 2/97 Metric: Technical Update: 2/97 POINT OF CONTACT: Dennis Grevel Phone: (303) 98768580*(( CXM s4 #d `7#`4!(#UFUSES Project Name (ftr B)` (#T[2/97] .16412   b-SECTION 16412 1FUSES PART 1: GENERAL 1.1SUMMARY A.Section Includes: [Furnishing] [and] [installing] fuses rated 600 V or less [in fused disconnect switches] [and elsewhere] [as shown on drawings].(# B.Related Sections:(# ************************************************** DELETE EITHER 01009 OR 01010. EITHER SECTION 01300 OR 01410 MUST BE USED WHEN 01010 IS USED. ************************************************** Summary of Work`(#MSection 01010 Submittals`(#MSection 01300 1.2SUBMITTALS A.General: Submittals shall be according to [Section 01009 General Information and Requirements.] [Section 01300 Submittals.] [Section 01365 Certificates of Conformance.](# B.Manufacturer's Literature: Submit [ ] copies of the manufacturer's technical data for the fuses to be used on this project.(# 1.3QUALITY ASSURANCE A.Labeling Requirements: Fuses shall be Underwriters Laboratories, Inc. (UL) listed and labeled. UL listing and labeling will not be required if it can be shown that fuses meet the requirements of another nationally recognized testing laboratory (NRTL).(#  PART 2: PRODUCTS 2.1MATERIALS A.General: Fuses shall be constructed of the manufacturer's standard materials, as listed in published product information; types and sizes shall be as indicated or as required for the installation.(# B.Fuse Types: Unless otherwise indicated, fuses rated 600 amperes or less shall be UL class [RK1] [RK5] as listed in UL 198E. Fuses rated more than 600 amperes shall be UL class L as listed in UL 198C.(# C.Fuses for Low Fault Current Circuits: Fuses on the secondary side of transformers or generators rated 37.5 KVA or less may be UL class H as listed in UL 198B.(# D.Plug Fuses: Fuses in circuits rated less than 25 amperes and 125 volts, may be UL Class S plug fuses as listed in UL 198F.(# E.Fuses for Coordination with Circuit Breakers: Shall be UL Class J or UL Class L as listed in UL 198C and shall be furnished by the circuit breaker manufacturer for coordinated selective protection.(# }&0*s's'ԌF.Ratings: Unless otherwise indicated, fuse ratings shall be as required by NFPA 70.(# G.Melting Time: Unless otherwise indicated, fuses feeding motors shall be time delay type. Other fuses shall be fast acting.(#  PART 3: EXECUTION 3.1INSTALLATION A.General: Install fuses as indicated, complying with the manufacturer's written instructions, applicable requirements of codes and standards, and according to recognized industry practices.(# B.Quantities: Provide two sets of fuses for each [fusible switch,] [fuse coordinated circuit breaker,] [and fuse block] [or other type of fuse holder.] Install one set in the appropriate fusible equipment and deliver the other set, in original boxes, to the Contracting Officer.(#  PART 4: MEASUREMENT AND PAYMENT ***************************************************** WHEN A "LUMP SUM" CONTRACT IS USED, DELETE THE TITLE PART 4: MEASUREMENT AND PAYMENT, AND BOTH ARTICLES FROM THIS SECTION. MEASUREMENT AND PAYMENT WILL BE ADDRESSED IN PART 4 OF SECTION 01010 SUMMARY OF WORK. ***************************************************** 4.1METHOD OF MEASUREMENT A.Units: The work described in this section will not be measured for payment.(# 4.2BASIS OF PAYMENT A.Payment: No direct payment for the work described under this section will be made. Consideration for this item shall be included in the bid price for other items of the Contract.(# 0,END OF SECTION