WPCP 2%B Tg WPrestige Elite 10pt 12 pitch (D/J/M)|Lddd,#d\( @HP LaserJet Series IIHPLASEII.PRSd\( @,,,,06O2 DFN*#|d +* * * * * * * * REMOVE THIS OUTLINE GUIDE BEFORE PLACING THE SPECIFICATION SECTION IN THE CONTRACT ,* * * * * * * * 'O U T L I N E G U I D E 'DIVISION 15: MECHANICALă "SECTION 15781 - PACKAGED HEAT PUMPS USE:X[Construction] [Maintenance] of Unique job requirements may require specific coverage in the following specification sections:(# X X` hp x (#%'X` hp x (#%'A.Section 01009: General Information and Requirements(# X (Must be used when Section 01010 is not used.)(# X B.Section 01010: Summary of Work(# X (Do not use when Section 01009 is used.)(# X C.Section 01019: Government-Furnished Property(# X (When Governmentfurnished material or equipment is used, this section must be included.)(# X D.Section 01300: Submittals(# X (When Contractorfurnished materials are used, [either] this section [or Section 01365] must be included when Section 01009 is not used.)(# X E.Section 01365: Certificates of Conformance(# X (When Contractorfurnished materials are used, [either] this section [or Section 01300] must be included when Section 01009 is not used.)(# X F.Section 01505: Mobilization(# X (Use when mobilization will be paid for separately.)(# X G.Section 01506: Temporary Construction Facilities(# X (Do not use when Section 01009 is used.)(# [FORMS] [DRAWING DATA] REQUIRED: Use the following [forms] [standard drawings] as appropriate; add Work Data Sheet, location, and detail drawings as needed:  h)ԌREQUIRED SPEC MODIFICATIONS: -GENERAL NOTESă X A.Whenever entire articles, paragraphs or subparagraphs are not applicable, the articles, paragraphs or subparagraphs should be deleted; if necessary, reletter or renumber articles, paragraphs or subparagraphs.(# X B.THIS GUIDE IS NOT INTENDED AS A SUBSTITUTE FOR READING THE ENTIRE SECTION.(# ,TECHNICAL NOTESă X A.1.01B: Select or add applicable specification sections. Do not list specification sections from Division 15.(# X B.4.01 and 4.02: When a "lump sum" Contract is used, delete the title PART 4: MEASUREMENT AND PAYMENT, and both articles from this section. Measurement and payment will be addressed in Part 4 of [Section 01009] [or] [Section 01010].(# X C.4.01A: When not a "lump sum" Contract, select applicable phrases; use the "no measurement" phrase when none of the Pay Items in this section are included in the Bid Schedule.(# X D.4.02A: When not a "lump sum" Contract, select applicable phrases; use the "no direct payment" phrase when none of the Pay Items in this section are included in the Bid Schedule.(# X E.When Governmentfurnished property is specified for Pay Items, the letter suffix GF will be added after the parenthesis of the item number.(# X` hp x (#%'@ X !=* * * * * * * * * * * * * * * @ =* POINT OF CONTACT * DATE OF LAST REVISION: 12/3/85+=* Del Garduno (SC673) * WRITTEN BY: Del Garduno$=* FTS 776-0128 * REVISED BY: Del Garduno$=* COMM. (303) 236-0128 * APPROVED BY: R.E. Enger$=* * * * * * * * * * * * * * * 115781 h)Ԍ@ X@ X(P .15781 (DIVISION 15 SECTION 15781 MECHANICAL PACKAGED HEAT PUMPS Rev. 12-85 PART 1: GENERAL 1.01 SUMMARY: A.@Section Includes: The work of this section consists of providing and installing a single package air source heat pump complete with automatic controls.(#@ 1.02 REFERENCES: A. American Refrigeration Institute:  @@ X@ XARI 210/240-84` (Unitary Air-Conditioning and Air-Source Heat Pump Equipment(#  @ARI 380-82L (Packaged Terminal Heat Pumps(# B. Underwriters' Laboratory:  @UL 559-85 ` (Heat Pumps(# 1.03 SUBMITTALS: A.@Data Requirements: Submit manufacturer's literature describing unit, parts list, and installation.(#@ 1.04 JOB CONDITIONS: A.@Delivery: Deliver material to job site in original non-broken factory packaging.(#@ B.@Protection: Protect unit from weather conditions.(#@ PART 2: PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS: A.@Unit: Unit shall be a standard product of a manufacturer regularly engaged in the manufacture of heating-cooling equipment. The manufacturer shall have parts and service available throughout the United States.(#@ 2.02 TYPE OF UNIT: A. Horizontal:  @1. Unit shall be capable of end handling of conditioned air.(#@  'ԌXxDIVISION 15 SECTION 15781 MECHANICAL PACKAGED HEAT PUMPS Rev. 1085 @@ X@ X2.Unit shall be single package, self-contained, factory-assembled and pre-wired consisting of cabinet and frame, supply fan, air filters, compressor, condenser coil and fan.(#  @3.Furnish and install optional minimum fresh air damper to provide outdoor air requirements. Damper box field installs external to duct enclosure and shall be manually operated.(# 2.03 PERFORMANCE: A.@DX Cooling System: The total certified cooling capacity shall not be less than [ ] BTUH with an indoor coil volume of [ ] cfm, an entering wet bulb air temperature of [ ]$F, and entering dry bulb air temperature of 80$F, and an outdoor coil entering temperature of [ ]$F.(#@ B.@Heating System: The total certified heating capacity shall not be less than [ ] BTUH with an indoor coil volume of [ ] cfm, an entering wet bulb air temperature of [ ]$F, an entering dry bulb temperature of [ ]$F, and an outdoor coil entering air temperature of [ ]$F. The total compressor power input shall not exceed [ ] kw at the above conditions.(#@ C.@Supplementary Electric Heating: The certified total heating capacity output shall be [ ] BTUH with [ ] kw input at [ ] volts, phase power supply.(#@  @1.Optimal electric heaters shall be field installed. Heating elements shall be nichrome bare wired exposed directly to the air system.(#  @2.Thermal time delay shall bring the elements on and off in sequence with a time delay between each element.(#  @3.Circuit breakers shall provide overload and short circuit protection. Safety devices shall consist of limit controls and thermal cutoff safety fuses. Heaters shall be UL listed.(# D.@Cabinet: Shall be galvanized steel with a baked-on outdoor enamel finish. Cabinet panels where conditioned air is handled shall be fully insulated to prevent sweating and minimize sound. Openings shall be provided for power connection entry. Base shall have drainage holes in outdoor coil section. Base support rails shall elevate unit off mounting surface.(#@ E.@Air Movers: Centrifugal conditioned air blower shall be direct driven by a multi-speed motor. Blower shall be capable of delivering [ ] cfm at an external static pressure of 0.5 inches water gauge requiring not more than [ ] hp and [ ] rpm. Blowers shall be statically and dynamically balanced.(#@  $ԌF.@Air Filters: Cleanable filters furnished shall have not less than [ ] square feet of free area.(#@ PART 3: EXECUTION 3.01 GENERAL: A.@Requirements: Unit will be completely factory-assembled, pre-charged, piped and wired internally ready for field connections. In addition, the manufacturer shall test operate system at the factory before shipment.(#@ 3.02 INSTALLATION: A.@Location: Place unit centered on concrete slab adjacent to building as shown on the drawings.(#@ B.@Connecting Ductwork: Connect ductwork to supply and return air sections of heat pump. Provide flexible duct connections near unit as shown on drawings.(#@ C.@Connections: Make power connections to unit as per electrical drawings and instructions. Provide connections to wall-mounted thermostat.(#@ PART 4: MEASUREMENT AND PAYMENT 4.01 METHOD OF MEASUREMENT: A.@Units: The work described in this section will not be measured for payment.(#@ 4.02 BASIS OF PAYMENT: A.@Payment: No direct payment for the work described under this section will be made. Contractor shall include consideration for this item in the bid price for other items of the Contract.(#@ ,END OF SECTION