ÿWPC(   RÈ% õìYú/ˆ–…&ï«ÈÊ^9E:¶Á’Ôn§W$çµ,œ}â”¶·a1F¤AƾùcÜø?+Ô Åß\Ï#}"'ûã }š-%ˆßÏs¢Ürö£iÁmÙwÑëçm-…mÒó ßxQ«áÿ½N8?Iƒ^ÐóðÆHmd-Ðþ¼¤fç£>›¡E¶Rd°¨]áÁ´:oïÆêHúãeöÁºV1º^T’:ýu*ÖPƒèƒÌPˆ¯óÓ,¼£õ7të®ó† /¥¸”€Ť,€ò òòòPó óóóage,Ð À+'2 Ðò òòòFóóó óooter,€ò òòòBóóó ó,€ò òòòEóóó ódit.€€Delete€the€"Project€Name€(ftr€B)"€text€and€replaceÐ ˆ,Ø'3 Ðit€with€the€ò òname€of€the€project€(bolded)ó ó.€€,€€until€you€arriveÐ ° Ðat€the€document€text.Ð €(#€(# ÐÌà0   àD.à0€ (# (#àThe€Guide€Specifications€are€being€reviewed€and€revised.€€YourÐ X Ðtechnical€comments€on€any€guide€spec€would€be€greatly€appreciated.€ÏAlso,€any€specs€that€are€written€"from€scratch"€that€would€benefitÏothers€could€be€sent€to€either€Dion€Dishong€or€Lori€Quayle,€RS„110.Ð €(#€(# ÐÌò òDRAWING€DATA€REQUIRED:ó ó€€Location€and€detail€drawings€as€needed,€showing€riserÐ ð @ Ðdiagrams€and€plans€as€appropriate.ÌÌò òREVISIONS€OF€THIS€SECTION:Ð H ˜  Ðó óCSI€format,€editorial€changes:€€2/97Ð `  ÐMetric:€€ÌTechnical€Update:€€2/97ÌPOINT€OF€CONTACT:€€Dennis€Grevel€€€Phone:€€(303)€236„9506ÌÐ  0€  ÐÖ€ÈÖÖ€ÿÿÖØØà@bb-ìàSECTION€13855ˆÌÌà@¦¦&ìàDETECTION€AND€ALARM€SYSTEMSˆÌÌÌòòPART€1:€€GENERALóóÐ ˜è ÐÌ1.1à0 € àSUMMARY:Ð( x€(#€(# ÐÌà   àA.à0 € àSection€Includes:€€[Furnishing]€[and]€[installing]€a€low-voltage,Ð ¸   Ðsolid-state,€modular,€electronic€system€capable€of€multizone€[fire]Ï[security]€[integrated€fire€and€security]€protection.Ð €(#€(# ÐÌà   àB.à0 € àRelated€Sections:ÐØ( €(#€(# ÐÌà   àà € àSummary€of€Workà  àà à àà À àà   àà € àà ` àà @ àSection€01010Ð h¸  Ðà   àà € àSubmittalsà àà  àà à àà À àà   àà € àà ` àà @ àSection€01300Ð 0€  Ðà   àà € àContract€Closeoutà  àà à àà À àà   àà € àà ` àà @ àSection€01700Ð øH  Ðà   àà € àFire/Smoke€Dampersà  àà à àà À àà   àà € àà ` àà @ àSection€15916Ð À ÐÌ1.3à0 € àSYSTEM€DESCRIPTION:ÐP €(#€(# ÐÌà   àA.à0 € àGeneral:€€Whenever€the€two€types€of€alarm€systems€are€used€in€the€sameÐ à0 Ðinstallation,€a€single€UL€listed€panel€which€provides€both€fire€andÏsecurity€alarm€functions€shall€be€used.€€Also,€the€alarm€indicatingÏdevices€shall€be€common€to€both€systems€where€feasible,€but€the€alarmÏinitiating€devices€and€circuits€shall€be€kept€separate.Ð €(#€(# ÐÌà   àB.à0 € àFire€Alarm€System:€€Includes€alarm€panel,€alarm-initiating€devices,Ð à Ðand€alarm-indicating€devices.€€System€shall€be€a€local,€non-coded,Ïprotective€signaling€system€as€described€in€NFPA€72.€€It€shall€includeÏ[2]€[4]€zones€of€[2-wire€class€B]€[4-wire€Class€A]€alarm€initiatingÏcircuits.€€It€shall€include€[1]€[2]€alarm€indicating€circuits€withÏindoor€and€outdoor€signaling€devices.€€An€automatic€telephone€dialerÏactuated€by€an€alarm€condition€is€also€required.Ð €(#€(# ÐÌà   àC.à0 € àSecurity€Alarm€System:€€Includes€alarm€panel,€alarm-initiatingÐ Ð $ Ðdevices,€and€alarm-indicating€devices.€€Initiating€and€indicatingÏcircuits€shall€be€supervised.€€Either€an€open€or€a€short€circuit€onÏalarm€initiating€circuit€of€fixed€or€movable€devices€shall€cause€aÏcontinuous€alarm€signal€until€the€operated€device€is€returned€toÏnormal€or€the€silence€button€is€pushed.€€One€zone€loop€shall€containÏthe€fixed€alarm€devices€which€shall€operate€when€the€system€is€inÏeither€secure€or€access€mode.€€Other€zone€loops€shall€containÏkey-operated€switches€to€transfer€the€movable€initiating€devices€inÏthe€zone€from€secure€to€access€mode.€€The€movable€devices€shall€notÏalarm€when€in€the€access€mode.€€A€short€time€delay€shall€allow€theÏoperator€of€the€secure-access€switch€time€to€enter€or€exit€theÏbuilding€before€the€alarm€is€triggered.Ð €(#€(# ÐÐ ø*H&1 Ð1.4à0 € àSUBMITTALS:а€(#€(# Ðà   àA.à0 € àGeneral:€€Submittals€shall€be€according€to€[Section€01009€„€GeneralÐ xÈ ÐInformation€and€Requirements.]€[Section€01300€-€Submittals.]€[SectionÏ01365€„€Certificates€of€Conformance.]Ð €(#€(# Ð**************************************************Ìà0   àINSERT€NUMBER€OF€COPIES€OF€THE€MANUFACTURERððS€DESCRIPTIVE€DATA€REQUIRED.€ÏNORMALLY€5€COPIES€ARE€REQUIRED.€€DISTRIBUTION€AFTER€REVIEW€IS€NORMALLY€1ÏCOPY€TO€THE€CO,€3€COPIES€TO€THE€CONTRACTOR,€AND€1€COPY€TO€THE€PROJECT€FILE.Ð  (# (# Ð**************************************************€€€€€€€€€ÌÌà   àB.à0 € àManufacturer's€Literature:€€Submit€[òò€€€€óó]€copies€of€the€manufacturer'sÐ € Ð  Ðdescriptive€data€for€the€following€items€to€be€used€on€this€project:Ð €(#€(# Ðà   àà € à1.à0 ` àAlarm€panelsÐ` ` (#` (# Ðà   àà € à2.à0 ` àInitiating€devicesÐØ( ` (#` (# Ðà   àà € à3.à0 ` àIndicating€devicesРð ` (#` (# Ðà   àà € à4.à0 ` àConductorsÐh¸ ` (#` (# Ðà   àà € à5.à0 ` àInternal€and€interconnection€wiring€diagramsÐ0€ ` (#` (# Ðà   àà € à6.à0 ` àSchematicsÐøH ` (#` (# ÐÌ1.5à0 € àQUALITY€ASSURANCE:Ј؀(#€(# ÐÌà   àA.à0 € àLabeling€Requirements:€€Alarm€and€detection€system€components€shall€beÐ h ÐUnderwriters€Laboratories,€Inc.€(UL)€listed€and€labeled.€€UL€listingÏand€labeling€will€not€be€required€if€it€can€be€shown€that€systemÏcomponents€meet€the€requirements€of€another€nationally€recognizedÏtesting€laboratory€(NRTL).Ð €(#€(# ÐÌÔ  ÔòòPART€2:€€PRODUCTSóóÐ È ÐÌ2.1à0 € àMATERIALS:ÐX¨€(#€(# ÐÌà   àA.à0 € àGeneral:€€Alarm€and€detection€system€components€shall€be€constructedÐ è8 Ðof€the€manufacturer's€standard€materials,€as€listed€in€publishedÏproduct€information;€types€and€sizes€shall€be€as€indicated€or€asÏrequired€for€the€installation.Ð €(#€(# ÐÌ2.2à0 € àEQUIPMENT:ÐÐ $€(#€(# ÐÌà   àA.à0 € àSystem€Control€Panel:€€NFPA€72€and€shall€include€[[òò€€€óó]€zones€for€fireÐ `"°& Ðalarm€initiating€circuits];€[[òò€€€óó]€zones€for€security€alarm€initiatingÐ (#x' Ðcircuits];€a€common€module€with€2€alarm€indicating€circuits;€a€commonÏmodule€with€power€supply€for€3-wire€single-phase€connection€andÏbattery€stand-by;€and€controls€for€trouble€indication€and€acknowledge,Ïalarm€silence€and€reset,€alarm-lamp€test,€and€telephone€dialer€actuateÏand€disconnect.Ð €(#€(# ÐÌà   àB.à0 € àFire€Alarm€Initiating€Devices€Shall€Include:Р(ð#.€(#€(# Ðà   àà € à1.à0 ` àAutomatic€Smoke€Detectors:€€NFPA€72E€and€shall€be€of€theÐ h)¸$/ Ð[photoelectric€type]€[ionization€type].€€They€shall€operate€on€24ÏV€dc€and€include€an€alarm€indicator€light.€€The€ionization€typeÐ ø*H&1 Ðshall€include€a€field€accessible€sensitivity€adjustment.€€Also€seeÏSection€15915€-€Fire/Smoke€Dampers.Ð ` (#` (# Ðà   àà € à2.à0 ` àAutomatic€Fire€Detectors:€€NFPA€72E€and€shall€be€of€the€[fixedÐ @ Ðtemperature]€[combination€fixed€temperature€and€rate-of-rise]Ïtype.€€Fixed€temperature€setting€shall€be€135€degrees€F€for€normalÏuse€or€200€degrees€F€for€use€adjacent€to€furnace€or€boiler.€ÏRate-of-rise€setting€shall€be€15€degreesF€per€minute.€€DetectorsÏshall€be€of€the€restorable€type,€and€shall€include€spare€partsÏneeded€for€restoration.Ð ` (#` (# Ðà   àà € à3.à0 ` àSprinkler€System€Switches:€Pressure€type€designed€to€operate€onÐ ¸   Ð[rising]€[falling]€pressure.€€The€operating€point€shall€be€ratedÏat€40€psi,€with€switch€operating€at€30€psi€and€restoring€at€33Ïpsi.€€Two€single-pole€single-throw€contacts€shall€be€provided€inÏthe€switch.Ð ` (#` (# Ðà   àà € à4.à0 ` àManual€Stations:€Non-coded,€break-glass€type,€general€alarmÐ  ð  Ðdevice.€€Station€to€be€[surface]€or€[semi-flush]€mounted€withÏsingle-pole,€single-throw€contact€switch.€€One€spare€glass€rodÏshall€be€included€with€each€station.Ð ` (#` (# Ð**************************************************€€€€€€€€€€€€€€€€€€€€€ÌADD€ADDITIONAL€DEVICES€AS€NEEDED.€€(LIST€AND€DESCRIGE€ANY€ADDITIONAL€SENSORSÏSUCH€AS€CAPACITANCE,€AUDIO,€VIBRATION,€INDOOR€MICROWAVE,€AMD€ULTRASONICÏDETECTORS.)Ì**************************************************€€€ÌC.à0 € àSecurity€Alarm€Initiating€Devices€Shall€Include:Шø€(#€(# Ðà   àà € à1.à0 ` àContact€Devices:€€Either€mechanical€or€magnetic€switches€areÐ pÀ Ðacceptable€for€use€on€doors,€windows,€or€covers.€€Switches€shallÏhave€single-pole€single-throw€(SPST)€contacts.€€Foil€(tapes)€ofÏtin-lead€material€may€be€used€to€detect€glass€breakage.Ð ` (#` (# Ðà   àà € à2.à0 ` àPhotoelectric€Beam€Detectors:€€Unit€shall€be€an€indoorÐ à Ðphotoelectric€system€using€an€invisible€modulated-infrared€beam.€ÏInterruption€of€the€beam€between€transmitter€and€receiver€shallÏcause€an€alarm€condition.€€Unit€shall€operate€on€12€V€ac€andÏinclude€an€indicator€to€show€an€alarm€condition.Ð ` (#` (# Ðà   àà € à3.à0 ` àPassive-Infrared-Motion€Sensor:€€Sensor€to€be€a€solid-state,Ð xÈ! Ðpassive-€infrared,€multibeam-motion€detector€for€wall€mounting,Ïwith€swivel€head€for€adjustable€coverage.€€Unit€shall€include€12€VÏdc€power€supply,€a€tamper€switch,€an€alarm€relay€and€a€walk-testÏlamp.€€The€walk-test€lamp€indicates€the€field€of€coverage.€ÏNominal€coverage€shall€be€25€ft€by€30€ft€by€6€ft€high.Ð ` (#` (# Ðà   àà € à4.à0 ` àMicrowave-Beam€Outdoor€Detector:€€Unit€shall€include€aÐ (#x' Ðtransmitter,€receiver,€swivel€mounts,€and€power€supply€in€aÏweatherproof€radome.€€Detection€pattern€shall€be€field€adjustableÏand€shall€extend€from€50€to€300€ft€long€by€5€to€15€ft€wide.€ÏOperating€temperature€shall€be€from€-30degrees€F€to€150€degreesÏF.Ð ` (#` (# Ðà   àà € à5.à0 ` àAdditional€Sensors:€€[òò€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€€Ð Ø'(#- Ðóó.]Р(ð#.` (#` (# ÐÌâ âà   àD.à0 € àIndicating€Devices€Shall€Include:Ð0*€%0€(#€(# Ðà   àà € à1.à0 ` àBells:€€6-inch€standard€vibrating€type€for€polarized€D.C.€24VÐ ° Ðâ âoperation;€indoor/outdoor€type.€€Maximum€current€draw€shall€beÏless€than€0.2€A.Ð ` (#` (# Ðà   àà € à2.à0 ` àHorns:€Weatherproof€construction.€€They€shall€be€for€use€onÐ X Ðpolarized€24€V€dc€with€maximum€current€draw€of€0.2€A€or€less.Ð ` (#` (# Ðà   àà € à3.à0 ` àAutomatic€Telephone€Dialer:€€Shall€be€approved€for€directÐ ˜è Ðinterconnect€by€the€FCC€and€acceptable€to€the€local€telephoneÏcompany€for€connection€on€their€system.€€The€dialer€shallÏincorporate€synthesized€voice€reporting€and€an€electronicÏmicroprocessor€with€keyboard€programming€to€allow€telephoneÏnumbers€to€be€reprogrammed.€€The€dialer€shall€be€a€two-channelÏtype€capable€of€dialing€at€least€two€different€numbers€dependingÏupon€whether€the€fire€or€the€security€panel€is€in€alarm€condition.Ð ` (#` (# ÐÌÔ  ÔòòPART€3:€€EXECUTIONóóÐ  ð  ÐÌ3.1à0 € àINSTALLATION:Ð0€ €(#€(# ÐÌà   àA.à0 € àGeneral:€€Install€alarm€and€detection€systems€as€indicated,€complyingÐ À Ðwith€manufacturer's€written€instructions,€applicable€requirements€ofÏcodes€and€standards,€and€according€to€recognized€industry€practices.Ð €(#€(# ÐÌà   àB.à0 € àMounting:€€Mount€alarm€and€detection€equipment€where€shown€on€theÐ à0 Ðdrawing€according€to€NFPA€72.€€Provide€required€interlocking€toÏheating,€ventilating,€and€air€conditioning.Ð €(#€(# Ðà   àà € à1.à0 ` àAutomatic€Fire€Detectors:€€Detectors€shall€not€be€recessed€intoÐ 8ˆ Ðbuilding€ceiling€and€shall€be€supported€independently€of€supplyÏcircuit.€€Spacing€shall€not€exceed€that€allowed€by€NFPA€72.Ð ` (#` (# Ðà   àà € à2.à0 ` àTamper€Protection:€€Install€tamper-proof€equipment€and€signalÐ à Ðcircuits€so€the€protection€is€functional.Ð ` (#` (# ÐÌ3.2à0 € àADJUSTING:Ðè8€(#€(# ÐÌà   àA.à0 € àRequirements:€€Alarm€equipment€shall€be€adjusted€by€the€ContractorÐ xÈ! Ðaccording€to€the€manufacturer's€written€instructions.Ð €(#€(# ÐÌ3.3à0 € àDEMONSTRATION:ÐÐ $€(#€(# ÐÌà   àA.à0 € àRequirements:€€In€addition€to€system€testing,€test€each€detector€andÐ `"°& Ðalarm€to€insure€its€correct€operation.€€€Correct€and€retestÏmalfunctioning€unitsñNññMñ.ñMññNññOñ€to€demonstrñOññPññLñ€€ñLññPñate€compliance€with€theÏspecifications.Ð €(#€(# ÐÌ3.4à0 € àTRAINING€OF€GOVERNMENT€EMPLOYEES:ÐH&˜!+€(#€(# ÐÌà   àA.à0 € àRequirements:€€See€Section€01700€„€Contract€Closeout.ÐØ'(#-€(#€(# Ðâ âòòÐ  (ð#. ÐÔ  Ôâ âPART€4:€€MEASUREMENT€AND€PAYMENTóóÐ ° ÐñQñšñQññSñ**************************************************ñSññTññSñ*ñSññTññRñÌñRññQñWHEN€A€"LUMP€SUM"€CONTRACT€IS€USED,€DELETE€THE€TITLE€PART€4:€€MEASUREMENT€ANDÏPAYMENT,€AND€BOTH€ARTICLES€FROM€THIS€SECTION.€€MEASUREMENT€AND€PAYMENT€WILL€BEÏADDRESSED€IN€PART€4€OF€SECTION€01009€OR€SECTION€01010.ÌñQññYññQñÌñQññYññXññQñWHEN€NOT€A€"LUMP€SUM"€CONTRACT,€SELECT€APPLICABLE€PHRASES;€USE€THE€"NOÏMEASUREMENT"€PHRASE€WHEN€NONE€OF€THE€PAY€ITEMS€IN€THIS€SECTION€ARE€INCLUDED€INÏTHE€BID€SCHEDULE.ÌñQññXññQñ*************************************************ñQññUññQñ****ñQññUññVñ*ñVññQñÌñQñÌ4.1à0 € àMETHOD€OF€MEASUREMENT:Ð( x€(#€(# ÐÌà   àA.à0 € àUnits:€€The€work€described€in€this€section€will€not€be€measured€forÐ ¸   Ðpayment.Ð €(#€(# ÐÌ4.2à0 € àBASIS€OF€PAYMENT:Ð` €(#€(# ÐñWñšñWññZññWñ*****************************************************ÌWHEN€NOT€A€"LUMP€SUM"€CONTRACT,€SELECT€APPLICABLE€PHRASES;€USE€THE€"NO€DIRECTÏPAYMENT"€PHRASE€WHEN€NONE€OF€THE€PAY€ITEMS€IN€THIS€SECTION€ARE€INCLUDED€IN€THEÏBID€SCHEDULE.€€ÌÌWHEN€NOT€A€"LUMP€SUM"€CONTRACT€AND€PAYMENT€IS€TO€BE€MADE€UNDER€THIS€SECTION,ÏSELECT€APPLICABLE€PAY€ITEMS.€€DO€NOT€CHANGE€PAY€ITEM€NUMBER.€€WHEN€MORE€THANÏONE€DIAMETER€OR€GAUGE€IS€SPECIFIED€FOR€ANY€PAY€ITEM,€LETTER€SUFFIXES€WILL€BEÏADDED€AFTER€THE€PARENTHESIS€OF€THE€ITEM€NUMBER.€€WHEN€GOVERNMENT„FURNISHEDÏPROPERTY€IS€SPECIFIED€FOR€PAY€ITEMS,€THE€LETTER€SUFFIX€GS€WILL€BE€ADDED€AFTERÏTHE€PARENTHESIS€OF€THE€ITEM€NUMBER.Ì*****************************************************ÌñWññZñÌà   àA.à0 € àPayment:€€No€direct€payment€for€the€work€described€under€this€sectionÐ  ð  Ðwill€be€made.€€Consideration€for€this€item€shall€be€included€in€theÏbid€price€for€other€items€of€the€Contract.Ð €(#€(# ÐÌÌÌà@00,ìàEND€OF€SECTION